Products

Lighthouse Worldwide Solutions LS-60 Liquid Sampler

24 January, 2011 | Particle & Surface Sciences Pty Ltd

The LS-60 Liquid Sampler from Lighthouse Worldwide Solutions is an integrated syringe sampler and optical particle counting system with an easy-to-use Windows-based software interface.

MIP Electronics particle emissions measuring equipment

24 January, 2011 | Particle & Surface Sciences Pty Ltd

MIP Electronics develops and manufactures optical measuring instruments for measuring particle emissions in stacks. MIP also delivers a range of equipment for measuring noise, vibration and indoor air quality and other features in the working environment. Particle and Surface Sciences is the sole distributor throughout Australia and New Zealand for the MIP product range.

Spill Station Hardcover Spill Pallet

24 January, 2011 | Spill Station Australia

The Hardcover Spill Pallet with a sump of 410 L is used to store drums in a secure bunded area.

Micromeritics HPVA-100 high-pressure volumetric analyser

24 January, 2011 | Particle & Surface Sciences Pty Ltd

Particle and Surface Sciences is the sole distributor throughout Australia and New Zealand for the Micromeritics HPVA-100 high-pressure volumetric analyser.

Mueller Accu-Therm plate heat exchanger

24 January, 2011 | Teralba Industries Pty Ltd

Mueller plate heat exchangers can be assembled to suit user requirements. Each exchanger is selected using software to match the specific performance requirements of individual applications. The units also incorporate an expandable design enabling an increase of heat transfer surface area without any changes to the unit footprint.

Dywer DX differential pressure switch

24 January, 2011 | Dwyer Instruments (Aust) Pty Ltd

The series DX differential pressure switch can be used for low differential pressure indication with setpoint on a decrease of pressure as low as 1 psid (0.07 bar). Differential setpoint ranges are available from 2.5 to 75 psid (0.17 to 5.17 bar) on increasing differential pressure and 1.0 to 67 psid (0.07 to 4.62 bar) on decreasing differential pressure. The unit features a high static pressure rating of 200 psig (13.8 bar) for higher static pressure applications. It comes standard with a weatherproof, UL type 4X enclosure for dust-laden, outdoor or washdown installation environments.

WeatherHawk 520 bushfire emergency weather stations

18 January, 2011 | Campbell Scientific Aust Pty Ltd

Fire professionals need powerful, portable technologies to assist in making strategic decisions in times of emergency, for resource planning and for scheduled fire management programs. The WeatherHawk 520 is a simple, quick, monitoring and reporting system that can be used in extreme environments to alert and notify of changing weather conditions. When bundled with a solar power supply, the station can work as a drop-and-run, back-to-base weather station, suitable for multiple placements when real-time reporting is essential.

Straub pipe repair clamp

16 January, 2011 | KCES Pty Ltd

The Straub clamp is used for the safe and reliable sealing of damaged pipes of all pipe materials.

Dwyer Instruments Series DX differential pressure switch

10 January, 2011 | Dwyer Instruments (Aust) Pty Ltd

The Series DX differential pressure switch makes a contact output based on the differential between two pressure sources.

Noshok 800 Series Platinum Resistance Temperature Transmitter

20 December, 2010 | AMS Instrumentation & Calibration Pty Ltd

The Noshok 800 Series Platinum Resistance Temperature Transmitter is suitable for immediate, accurate temperature measurement in applications including water systems, storage tanks, industrial machinery and machine tools, HVAC systems and refrigeration systems.

Innovia Films NatureFlex N913 cellulose-based packaging film

20 December, 2010 | Innovia Films Pty Ltd

The NatureFlex N913 is the latest grade of NatureFlex cellulose-based packaging film. Derived from renewable resources, the film has a sealant layer for enhanced sealability and seal integrity. Other advantages of the product include providing a barrier to moisture, gases and aromas; and certified to meet the European EN 13432 and American ASTM D6400 composting norms.

Aussie Scud high-pressure cleaning system

20 December, 2010 | Australian Pump Industries Pty Ltd

The Aussie Scud series system is a complete range of pressure cleaners and accessories designed to provide more cost-effective cleaning solutions, with minimal environmental impact.

KSB RDLO axially split case water pumps

20 December, 2010 | KSB Australia Pty Ltd

When KSB designed its RDLO range of axially split case water pumps, many years of experience were taken into consideration across different aspects of user needs including high efficiency, the performance range, low NPSH requirements and the benefits of easier maintenance. Many of the features are an extension from the smaller Omega series.

Philips dimmable 12 W Master LEDbulb

29 November, 2010 | Signify

The Philips dimmable 12 W Master LEDbulb is an LED replacement for a 60 W incandescent light bulb.

Palintest Manganese HR test

29 November, 2010 | Palintest Ltd

The Manganese HR test from Palintest is a high-range test for manganese in drinking water. It has a measurement range of 0.02 to 5 mg/L, without the need for pre-test sample dilution.

  • All content Copyright © 2024 Westwick-Farrow Pty Ltd