Endress+Hauser TOCII CA72 analyser
01 February, 2010 | Endress+Hauser Australia Pty Ltd
The continuous and batch monitoring of TOC (total organic carbon) in industrial wastewater is now much simpler and more cost effective with the TOCII CA72 analyser. Industrial, manufacturing and process plants need to be extremely careful in treating their wastewater. The TOC levels must be carefully monitored and the wastewater adequately treated before being discharged into the municipal system. Too-high levels result in severe penalties.
Turck PT4500 and PT4510 submersible pressure transmitters
14 January, 2010 | Turck Australia Pty Ltd
Turck’s PT4500 and PT4510 submersible pressure transmitters are optimised for detecting the level of water or other media with similar density in challenging industrial environments - including in wastewater and irrigation systems, as well as tanks containing liquids such as gas and diesel.
C&D recycling facility
14 January, 2010 | Alex Fraser Recycling
The $45 million Western Metropolitan Recycling Facility, owned and operated by the Alex Fraser Group, has been opened in Melbourne.
Exair Chip Trapper vacuum for contaminated liquid
14 January, 2010 | Compressed Air Australia Pty Ltd
Exair’s Chip Trapper offers a fast and easy way to clean solids such as chips, swarf and shavings out of used coolants and other liquids. The unit vacuums the coolant or liquid that is filled with debris into the included 208 L drum, trapping all the solids in a re-usable filter bag. With a turn of the flow valve, clean liquid pumps back out. Expensive coolant that used to last only six weeks can now last longer with regular use of the Chip Trapper. The unit is suitable for use on machines with sumps, parts washers, tanks and storage containers.
Capital Controls Series 70CV3000 Chloromatic Gas Flow Control Valve
14 January, 2010 | Severn Trent Services
The Capital Controls Series 70CV3000 Chloromatic Intelligent Gas Flow Control Valve is a wall-mounted system designed to control chemical feed in water or wastewater applications.
Electronic Sensor Technology (EST) 4500 zNose portable gas chromatographer
14 January, 2010 | Technical & Scientific Equipment
The 4500 zNose portable gas chromatographer, from Electronic Sensor Technology (EST), is a mobile, small footprint analyser that can accurately detect and analyse organic, biological and chemical compounds in real time.
ItN Nanovation CFM Systems for biological wastewater purification
14 January, 2010 | Reaman Industries Ltd
CFM Systems is a ceramic flat membrane system for biological wastewater purification. Suitable for submerged filtration processes, the ItN Nanovation product is now being introduced to the New Zealand water and wastewater industry. It should be available early 2010 for demonstrations and pilot trials.
SonTek Argonaut SW series of acoustic current meters
14 January, 2010 | Thermo Fisher Scientific
Designed with surface-mount electronics and Doppler technology, SonTek’s Argonaut series of acoustic current meters is designed for accuracy in velocity measurements. The meters are available in several configurations, making them suitable for a wide range of applications.
mySmart EBMPIR miniature presence detector
14 January, 2010 | mySmart Pty Ltd
The mySmart EBMPIR is a small 360° detector measuring just 28 mm (ceiling mounted 38 mm) with all the features of a larger size detector. It has a range of 5 m (diameter) and controls various types of lighting: fluorescent, CFL and low voltage.
Dwyer Instruments WMT multi-jet water meter with pulse output
14 January, 2010 | Dwyer Omega (Aust) Pty Ltd
The series WMT multi-jet water meter with pulse output is suitable for commercial and industrial applications. The multi-jet design allows simplicity and accuracy with wide flow ranges, even in low flow applications.
Hawk Sultan 234 series of acoustic wave level transmitters
14 January, 2010 | Hawk Measurement Systems Pty Ltd
The Hawk Sultan 234 series of acoustic wave level transmitters can be powered using loop power (2-wire), 3- or 4-wire sources. The instruments emit an acoustic wave pulse, which is then reflected from the surface of the material being measured. The reflected signal is processed using specially developed software to enhance the correct signal and reject false or spurious echoes. The measured signal is temperature compensated to provide maximum accuracy to the outputs and display.
Dwyer Series WMT multi-jet water meter with pulse output
14 January, 2010 | Dwyer Omega (Aust) Pty Ltd
The Series WMT multi-jet water meter with pulse output is suitable for commercial and industrial applications.
H2O Rx ECO valve
14 January, 2010 | H2O Rx
Excess pressure build-up can compromise fluid systems and destroy expensive pumps and fittings. Siphoning can lead to chemical wastage and loss of process control, and a lack of sufficient back pressure can lead to inaccuracies in metering of chemicals. The H2O Rx ECO Valve can be used to address all these complications.
Dwyer Instruments series UXF3 ultrasonic flowmeter converters
14 January, 2010 | Dwyer Omega (Aust) Pty Ltd
The series UXF3 ultrasonic flowmeter converters are paired with series SX1 or SX2 sensors in order to use the transit-time measure method. Using microprocessor-based electronics, the flowmeter can be configured from the front keypad to specific applications.
Macquarie Industrial Solutions surface sanitiser and disinfectant
24 November, 2009 | Macquarie Industrial Solutions
Macquarie Industrial Solutions' BioSpray D2 Surface Sanitiser and Disinfectant is a proprietary blend of isopropyl alcohol and quaternary ammonium solution with hospital-grade disinfecting killing power that is non-corrosive, non-staining and non-toxic.